Not only will regular maintenance by a Laser Repair Technician maintain your system safe and secure, but it will also save you money by preventing laser damage and downtime, resulting in efficient treatments for your clients. Keep in mind that owning and managing an attractive laser system involves considerable responsibility. Its upkeep is essential for your organization, you, and your customers.

 

Maintenance Advice for Aesthetic Lasers

 

Daily Cooling System Check

 

The cooling system also requires daily inspections before you activate the laser to prevent overheating. Check the cooling system levels before operating the laser equipment. Make careful you use deionized water and a coolant additive if necessary. The laser cavity and, in certain situations, the power supply, and handpieces are cooled by the coolant system. Your system might overheat if you neglect to monitor the water cavity.


Laser Repair Technician

 

Dust filters

 

Filters, vents on side panels, and fans should all be periodically dusted and vacuumed. The main cause of electrical and optical failures is dust. Dust and debris hinder your aesthetic laser from cooling down correctly, which might result in component and electrical damage. Cleaning the areas where you utilize the laser can help stop the future buildup of junk on the filter and vents. You can opt for Lumenis Repair.

 

Not Filling Laser Equipment Too Much

 

Make sure you're using deionized or distilled water as the manufacturer has advised. You might also need to add more coolant if your laser demands it. It's crucial not to overfill the tank, though. Don't overfill your laser by adding too much coolant. This may cause water to flow out of the reservoir, come too close to important electronics, and cause damage.


Laser Repair Technician

 

Check the pulses of the flash lamp

 

Track each wavelength's flash lamp pulses. It is advised that you switch out the bulbs after 500,000 pulses. Purchase fresh flashlights as needed.

 

Check Voltage

 

Check to see if the voltage tab in the laser system and the voltage in the wall are in sync. Although most facilities vary and the wall voltage might be as low as 200v or as high as 250v, a laser system normally works on 220v.

 

Maintain a cool treatment area.

 

Maintain the lowest feasible room temperature for your therapy. Air cooling is used to cool the laser system and related chiller. Overheating issues might happen in rooms that are over 75 to 80 degrees. Many prefer to go for Cutera Repair.